CVE-2021-25660: siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware
Vulnerability summary
CVE-2021-25660 is a high (CVSS 7.5) vulnerability in siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware. EPSS estimates a 0.97% chance of exploitation in the next 30 days, higher than 61.2% of scored vulnerabilities.
Timeline
- 12-05-2021PublishedVulnerability first disclosed.
- 02-06-2026Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
CVSS metrics
3 scores · 2 sources · 2 versions- NVDNIST7.5HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS trend
Probability
0.97%
Chance of exploitation in the next 30 days
Percentile
61%
Versus all other CVEs
30-day change
0.00 pp
From 0.97% on 20-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-788Access of Memory Location After End of BufferThe product reads or writes to a buffer using an index or pointer that references a memory location after the end of the buffer.
- CWE-119Improper Restriction of Operations within the Bounds of a Memory BufferThe product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.
Affected systems
Siemens18 products
- simatic_hmi_comfort_outdoor_panels_15\"_firmware< 16 | 16 | 16:update1 | 16:update2 | 16:update3 | < 15.1 | 15.1 | 15.1:update1 | 15.1:update2 | 15.1:update3 | 15.1:update4 | 15.1:update5
- simatic_hmi_comfort_outdoor_panels_7\"_firmware< 16 | 16 | 16:update1 | 16:update2 | 16:update3 | < 15.1 | 15.1 | 15.1:update1 | 15.1:update2 | 15.1:update3 | 15.1:update4 | 15.1:update5
- simatic hmi comfort outdoor panels v15 7\" & 15\" (incl. siplus variants)All versions < V15.1 Update 6
- simatic hmi comfort outdoor panels v16 7\" & 15\" (incl. siplus variants)All versions < V16 Update 4
- simatic_hmi_comfort_panels_22\"_firmware< 16 | 16 | 16:update1 | 16:update2 | 16:update3 | < 15.1 | 15.1 | 15.1:update1 | 15.1:update2 | 15.1:update3 | 15.1:update4 | 15.1:update5
1 vendor · 18 products