CVE-2021-27385: siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware Uncontrolled Resource Consumption
Vulnerability summary
CVE-2021-27385 is a high (CVSS 7.5) Uncontrolled Resource Consumption vulnerability in siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware. EPSS estimates a 2.56% chance of exploitation in the next 30 days, higher than 84.8% of scored vulnerabilities.
Timeline
- 12-05-2021PublishedVulnerability first disclosed.
- 02-06-2026Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
CVSS metrics
3 scores · 2 sources · 2 versions- NVDNIST7.5HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS trend
Probability
2.56%
Chance of exploitation in the next 30 days
Percentile
85%
Versus all other CVEs
30-day change
0.00 pp
From 2.56% on 19-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-400Uncontrolled Resource ConsumptionThe product does not properly control the allocation and maintenance of a limited resource.
- CWE-835Loop with Unreachable Exit Condition ('Infinite Loop')The product contains an iteration or loop with an exit condition that cannot be reached, i.e., an infinite loop.
Affected systems
Siemens26 products
- simatic_hmi_comfort_outdoor_panels_15\"_firmware< 16 | 16 | 16:update1 | 16:update2 | 16:update3 | < 15.1 | 15.1 | 15.1:update1 | 15.1:update2 | 15.1:update3 | 15.1:update4 | 15.1:update5
- simatic_hmi_comfort_outdoor_panels_7\"_firmware< 16 | 16 | 16:update1 | 16:update2 | 16:update3 | < 15.1 | 15.1 | 15.1:update1 | 15.1:update2 | 15.1:update3 | 15.1:update4 | 15.1:update5
- simatic hmi comfort outdoor panels v15 7\" & 15\" (incl. siplus variants)All versions < V15.1 Update 6
- simatic hmi comfort outdoor panels v16 7\" & 15\" (incl. siplus variants)All versions < V16 Update 4
- simatic_hmi_comfort_panels_22\"_firmware< 16 | 16 | 16:update1 | 16:update2 | 16:update3 | < 15.1 | 15.1 | 15.1:update1 | 15.1:update2 | 15.1:update3 | 15.1:update4 | 15.1:update5
1 vendor · 26 products
References
3 links- us-cert.cisa.gov/ics/advisories/icsa-21-131-12X Refsource MISCThird Party AdvisoryUS Government Resource