8.7

CVE-2022-38371: siemens apogee mbc (ppc) (bacnet) Uncontrolled Resource Consumption

CVSS: 8.7v4.0HighModified
Published 11-10-2022Last modified 13-05-2025

Vulnerability summary

CVE-2022-38371 is a high (CVSS 8.7) Uncontrolled Resource Consumption vulnerability in siemens apogee mbc (ppc) (bacnet). EPSS estimates a 1.59% chance of exploitation in the next 30 days, higher than 75.2% of scored vulnerabilities.

Overall risk
35/100
0100
Medium · default modelHow is this calculated?
CVSS score
8.7/10
010
High · v4.0 (CVE.org)
EPSS score
1.59%
0%100%
Low · +0.21 pp in 30 days
KEVNot listedIn no KEV catalog
RansomwareNone recordedNo known use recorded
Public exploits0No public exploits recorded

Timeline

  1. 11-10-2022
    PublishedVulnerability first disclosed.
  2. 13-05-2025
    Last modifiedVulnerability information updated.

Description

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC00-U (All versions >= V2.3 < V6.30.37), Desigo PXC001-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC100-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC12-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC128-U (All versions >= V2.3 < V6.30.37), Desigo PXC200-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC50-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC64-U (All versions >= V2.3 < V6.30.37), Desigo PXM20-E (All versions >= V2.3 < V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.

CVSS metrics

4 scores · 2 sources · 2 versions

EPSS trend

Probability

1.59%

Chance of exploitation in the next 30 days

Percentile

75%

Versus all other CVEs

30-day change

+0.21 pp

From 1.37% on 19-09-2026

19-09-202619-10-2026
EPSS score
1.59%

Known exploited

Compare KEV catalogs

Not in any of the 3 tracked catalogs.

Public exploits

0 found

No public exploits indexed.

Weaknesses

CWE · root cause

Affected systems

Siemens28 products

1 vendor · 28 products

References

4 links