CVE-2022-45104: dell evasa_provider_virtual_appliance Command Injection
CVSS: 8.8v3.1HighModified
Published 10-02-2023Last modified 24-03-2025
Vulnerability summary
CVE-2022-45104 is a high (CVSS 8.8) Command Injection vulnerability in dell evasa_provider_virtual_appliance. EPSS estimates a 1.38% chance of exploitation in the next 30 days, higher than 71.7% of scored vulnerabilities.
CVSS score
8.8/10
010
High · v3.1 (CVE.org)EPSS score
1.38%
0%100%
Low · 0.00 pp in 30 daysKEVNot listedIn no KEV catalog
RansomwareNone recordedNo known use recorded
Public exploits0No public exploits recorded
Timeline
- 10-02-2023PublishedVulnerability first disclosed.
- 24-03-2025Last modifiedVulnerability information updated.
Description
Dell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain a command execution vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to execute arbitrary commands on the underlying system.
CVSS metrics
2 scores · 2 sources · 1 versionHigh 8.8Preferred score · CVE.org (CNA)
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HSourcesAll 2 agree
- NVDNIST8.8HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS trend
Probability
1.38%
Chance of exploitation in the next 30 days
Percentile
72%
Versus all other CVEs
30-day change
0.00 pp
From 1.38% on 20-09-2026
20-09-202620-10-2026
EPSS score1.38%
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
- CWE-78Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
Affected systems
Dell4 products
- evasa_provider_virtual_appliance< 9.2.4.15
- solutions_enabler_virtual_appliance< 9.2.3.6 | < 9.2.4.26
- unisphere for powermax vapp≤ 9.2.3.x
- unisphere_for_powermax_virtual_appliance< 9.2.4.26
1 vendor · 4 products