CVE-2022-47375: siemens simatic_pc-station_plus_firmware
Vulnerability summary
CVE-2022-47375 is a high (CVSS 7.5) vulnerability in siemens simatic_pc-station_plus_firmware. EPSS estimates a 0.72% chance of exploitation in the next 30 days, higher than 52.8% of scored vulnerabilities.
Timeline
- 12-12-2023PublishedVulnerability first disclosed.
- 03-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.
CVSS metrics
2 scores · 2 sources · 1 version- NVDNIST7.5HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS trend
Probability
0.72%
Chance of exploitation in the next 30 days
Percentile
53%
Versus all other CVEs
30-day change
0.00 pp
From 0.72% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-805Buffer Access with Incorrect Length ValueThe product uses a sequential operation to read or write a buffer, but it uses an incorrect length value that causes it to access memory that is outside of the bounds of the buffer.
- CWE-119Improper Restriction of Operations within the Bounds of a Memory BufferThe product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.
Affected systems
Siemens10 products
- simatic_pc-station_plus_firmwareAll versions (No fix recorded)
- simatic s7-400 cpu 412-2 pn v7All versions (No fix recorded)
- simatic s7-400 cpu 414-3 pn/dp v7All versions (No fix recorded)
- simatic s7-400 cpu 414f-3 pn/dp v7All versions (No fix recorded)
- simatic s7-400 cpu 416-3 pn/dp v7All versions (No fix recorded)
1 vendor · 10 products
References
1 links- cert-portal.siemens.com/productcert/pdf/ssa-892915.pdfVendor Advisory