Siemens vulnerabilities, page 5
2,410 vulnerabilities
Known vulnerabilities in Siemens products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 4,015 products.
CriticalCVE-2018-20749canonical · ubuntu_linux +11 morecanonical ubuntu_linuxLibVNC before 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.EPSS3.23%CriticalCVE-2018-20750canonical · ubuntu_linux +12 morecanonical ubuntu_linuxLibVNC through 0.9.12 contains a heap out-of-bounds write vulnerability in libvncserver/rfbserver.c. The fix for CVE-2018-15127 was incomplete.EPSS3.33%CriticalCVE-2018-20019canonical · ubuntu_linux +11 morecanonical ubuntu_linuxLibVNC before commit a83439b9fbe0f03c48eb94ed05729cb016f8b72f contains multiple heap out-of-bound write vulnerabilities in VNC client code that can result remote code executionEPSS9.47%MediumCVE-2018-20685Alpine Linuxalpine · dropbear +27 morealpine dropbearIn OpenSSH 7.9, scp.c in the scp client allows remote SSH servers to bypass intended access restrictions via the filename of . or an empty filename. The impact is modifying the permissions of the target directory on the client side.EPSS3.68%CriticalCVE-2018-20748canonical · ubuntu_linux +13 morecanonical ubuntu_linuxLibVNC before 0.9.12 contains multiple heap out-of-bounds write vulnerabilities in libvncclient/rfbproto.c. The fix for CVE-2018-20019 was incomplete.EPSS3.26%HighCVE-2018-4836siemens ag · telecontrol server basic +1 moresiemens ag telecontrol server basicA vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations.EPSS1.80%HighCVE-2018-4832siemens · openpcs_7 +35 moresiemens openpcs_7A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.EPSS2.42%CriticalCVE-2018-4853siemens ag · siclock tc100, siclock tc400 +2 moresiemens ag siclock tc100, siclock tc400A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.EPSS2.27%HighCVE-2018-4845siemens ag · rapidlab 1200 systems / rapidpoint 400 systems / rapidpoint 500 systems, rapidlab 1200 series, rapidpoint 500 systems, rapidpoint 500 systems, rapidpoint 500 systems, rapidpoint 400 systems +3 moresiemens ag rapidlab 1200 systems / rapidpoint 400 systems / rapidpoint 500 systems, rapidlab 1200 series, rapidpoint 500 systems, rapidpoint 500 systems, rapidpoint 500 systems, rapidpoint 400 systemsA vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.EPSS1.16%CriticalCVE-2018-4858siemens ag · iec 61850 system configurator, digsi 5 (affected as iec 61850 system configurator is incorporated), digsi 4, sicam pas/pqs, sicam pq analyzer, sicam scc +6 moresiemens ag iec 61850 system configurator, digsi 5 (affected as iec 61850 system configurator is incorporated), digsi 4, sicam pas/pqs, sicam pq analyzer, sicam sccA vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.EPSS1.81%HighCVE-2018-4851siemens ag · siclock tc100, siclock tc400 +2 moresiemens ag siclock tc100, siclock tc400A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed.EPSS1.46%MediumCVE-2018-4844siemens ag · simatic wincc oa ui for android, simatic wincc oa ui for ios +1 moresiemens ag simatic wincc oa ui for android, simatic wincc oa ui for iosA vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.EPSS0.42%MediumCVE-2018-4856siemens ag · siclock tc100, siclock tc400 +2 moresiemens ag siclock tc100, siclock tc400A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users.EPSS1.28%MediumCVE-2018-4842siemens · scalance x-200irt switch family (incl. siplus net variants) +5 moresiemens scalance x-200irt switch family (incl. siplus net variants)A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.EPSS0.83%HighCVE-2018-4833siemens · rfid_181-eip_firmware +14 moresiemens rfid_181-eip_firmwareA vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.EPSS0.95%HighCVE-2018-4838siemens ag · en100 ethernet module dnp3 variant +9 moresiemens ag en100 ethernet module dnp3 variantA vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.EPSS1.40%HighCVE-2018-4837siemens ag · telecontrol server basic +1 moresiemens ag telecontrol server basicA vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with access to the TeleControl Server Basic's webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition.EPSS2.66%MediumCVE-2018-4835siemens ag · telecontrol server basic +1 moresiemens ag telecontrol server basicA vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.EPSS2.21%CriticalCVE-2018-4834siemens · desigo pxc00-e.d v4.10 +48 moresiemens desigo pxc00-e.d v4.10A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions < V4.10.111), Desigo PXC00-E.D V5.00 (All versions < V5.0.171), Desigo PXC00-E.D V5.10 (All versions < V5.10.69), Desigo PXC00-E.D V6.00 (All versions < V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions < V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions < V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions < V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (All versions < V6.0.204 only with web module), Desigo PXC001-E.D V4.10 (All versions < V4.10.111), Desigo PXC001-E.D V5.00 (All versions < V5.0.171), Desigo PXC001-E.D V5.10 (All versions < V5.10.69), Desigo PXC001-E.D V6.00 (All versions < V6.0.204), Desigo PXC100-E.D V4.10 (All versions < V4.10.111), Desigo PXC100-E.D V5.00 (All versions < V5.0.171), Desigo PXC100-E.D V5.10 (All versions < V5.10.69), Desigo PXC100-E.D V6.00 (All versions < V6.0.204), Desigo PXC12-E.D V4.10 (All versions < V4.10.111), Desigo PXC12-E.D V5.00 (All versions < V5.0.171), Desigo PXC12-E.D V5.10 (All versions < V5.10.69), Desigo PXC12-E.D V6.00 (All versions < V6.0.204), Desigo PXC200-E.D V4.10 (All versions < V4.10.111), Desigo PXC200-E.D V5.00 (All versions < V5.0.171), Desigo PXC200-E.D V5.10 (All versions < V5.10.69), Desigo PXC200-E.D V6.00 (All versions < V6.0.204), Desigo PXC22-E.D V4.10 (All versions < V4.10.111), Desigo PXC22-E.D V5.00 (All versions < V5.0.171), Desigo PXC22-E.D V5.10 (All versions < V5.10.69), Desigo PXC22-E.D V6.00 (All versions < V6.0.204), Desigo PXC22.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC22.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC22.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC22.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC36.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC36.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC36.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC36.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC50-E.D V4.10 (All versions < V4.10.111), Desigo PXC50-E.D V5.00 (All versions < V5.0.171), Desigo PXC50-E.D V5.10 (All versions < V5.10.69), Desigo PXC50-E.D V6.00 (All versions < V6.0.204), Desigo PXM20-E V4.10 (All versions < V4.10.111), Desigo PXM20-E V5.00 (All versions < V5.0.171), Desigo PXM20-E V5.10 (All versions < V5.10.69), Desigo PXM20-E V6.00 (All versions < V6.0.204). A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication.EPSS3.33%CriticalCVE-2018-4841siemens ag · tim 1531 irc +1 moresiemens ag tim 1531 ircA vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it.EPSS4.73%