CVE-2018-16557: siemens simatic_s7-400_firmware
Vulnerability summary
CVE-2018-16557 is a high (CVSS 8.2) vulnerability in siemens simatic_s7-400_firmware. EPSS estimates a 0.82% chance of exploitation in the next 30 days, higher than 56.5% of scored vulnerabilities.
Timeline
- 13-12-2018PublishedVulnerability first disclosed.
- 05-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102/tcp via Ethernet interface via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service condition on affected devices. Flashing with a firmware image may be required to recover the CPU. Successful exploitation requires an attacker to have network access to port 102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or Multi Point Interfaces (MPI) to the device. No user interaction is required. If no access protection is configured, no privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.
CVSS metrics
3 scores · 2 sources · 2 versions- NVDNIST8.2HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H
EPSS trend
Probability
0.82%
Chance of exploitation in the next 30 days
Percentile
56%
Versus all other CVEs
30-day change
0.00 pp
From 0.82% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root causeAffected systems
Siemens24 products
- simatic_s7-400_firmware≤ v6.0
- simatic s7-400 cpu 412-1 dp v7All versions (No fix recorded)
- simatic s7-400 cpu 412-2 dp v7All versions (No fix recorded)
- simatic s7-400 cpu 412-2 pn v7All versions < V7.0.3
- simatic s7-400 cpu 414-2 dp v7All versions (No fix recorded)
1 vendor · 24 products
References
1 links- cert-portal.siemens.com/productcert/pdf/ssa-113131.pdfVendor Advisory