CVE-2019-6572: siemens ag simatic hmi classic devices (tp/mp/op/mp mobile panel)
Vulnerability summary
CVE-2019-6572 is a critical (CVSS 9.1) vulnerability in siemens ag simatic hmi classic devices (tp/mp/op/mp mobile panel). EPSS estimates a 2.72% chance of exploitation in the next 30 days, higher than 85.8% of scored vulnerabilities.
Timeline
- 14-05-2019PublishedVulnerability first disclosed.
- 04-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVSS metrics
2 scores · 1 source · 2 versionsEPSS trend
Probability
2.72%
Chance of exploitation in the next 30 days
Percentile
86%
Versus all other CVEs
30-day change
0.00 pp
From 2.72% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-200Exposure of Sensitive Information to an Unauthorized ActorThe product exposes sensitive information to an actor that is not explicitly authorized to have access to that information.
- CWE-798Use of Hard-coded CredentialsThe product contains hard-coded credentials, such as a password or cryptographic key.
Affected systems
Siemens9 products
- simatic_hmi_comfort_outdoor_panels_firmware< 15.1
- simatic_hmi_comfort_panels_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp400f_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp700_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp700f_firmware< 15.1
Siemens ag7 products
- simatic hmi classic devices (tp/mp/op/mp mobile panel)All versions (No fix recorded)
- simatic hmi comfort outdoor panels 7" & 15"All versions < V15.1 Update 1
- simatic hmi comfort panels 4" - 22"All versions < V15.1 Update 1
- simatic hmi ktp mobile panels ktp400f, ktp700, ktp700f, ktp900 und ktp900fAll versions < V15.1 Update 1
- simatic wincc runtime advancedAll versions < V15.1 Update 1