CVE-2019-6577: siemens ag simatic hmi classic devices (tp/mp/op/mp mobile panel)
Vulnerability summary
CVE-2019-6577 is a medium (CVSS 5.4) vulnerability in siemens ag simatic hmi classic devices (tp/mp/op/mp mobile panel). EPSS estimates a 0.88% chance of exploitation in the next 30 days, higher than 58.2% of scored vulnerabilities.
Timeline
- 14-05-2019PublishedVulnerability first disclosed.
- 04-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
CVSS metrics
2 scores · 1 source · 2 versionsEPSS trend
Probability
0.88%
Chance of exploitation in the next 30 days
Percentile
58%
Versus all other CVEs
30-day change
0.00 pp
From 0.88% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-80Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)The product receives input from an upstream component, but it does not neutralize or incorrectly neutralizes special characters such as "<", ">", and "&" that could be interpreted as web-scripting elements when they are sent to a downstream component that processes web pages.
- CWE-79Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
Affected systems
Siemens9 products
- simatic_hmi_comfort_outdoor_panels_firmware< 15.1
- simatic_hmi_comfort_panels_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp400f_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp700_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp700f_firmware< 15.1
Siemens ag7 products
- simatic hmi classic devices (tp/mp/op/mp mobile panel)All versions (No fix recorded)
- simatic hmi comfort outdoor panels 7" & 15"All versions < V15.1 Update 1
- simatic hmi comfort panels 4" - 22"All versions < V15.1 Update 1
- simatic hmi ktp mobile panels ktp400f, ktp700, ktp700f, ktp900 und ktp900fAll versions < V15.1 Update 1
- simatic wincc runtime advancedAll versions < V15.1 Update 1
2 vendors · 16 products
References
3 links- www.us-cert.gov/ics/advisories/ICSA-19-134-09X Refsource MISC