CVE-2019-6576: siemens ag simatic hmi classic devices (tp/mp/op/mp mobile panel) Cryptographic Issues
Vulnerability summary
CVE-2019-6576 is a high (CVSS 7.5) Cryptographic Issues vulnerability in siemens ag simatic hmi classic devices (tp/mp/op/mp mobile panel). EPSS estimates a 1.75% chance of exploitation in the next 30 days, higher than 77.4% of scored vulnerabilities.
Timeline
- 14-05-2019PublishedVulnerability first disclosed.
- 02-06-2026Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
CVSS metrics
4 scores · 2 sources · 3 versions- NVDNIST6.5MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS trend
Probability
1.75%
Chance of exploitation in the next 30 days
Percentile
77%
Versus all other CVEs
30-day change
0.00 pp
From 1.75% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root causeAffected systems
Siemens9 products
- simatic_hmi_comfort_outdoor_panels_firmware< 15.1
- simatic_hmi_comfort_panels_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp400f_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp700_firmware< 15.1
- simatic_hmi_ktp_mobile_panels_ktp700f_firmware< 15.1
Siemens ag7 products
- simatic hmi classic devices (tp/mp/op/mp mobile panel)All versions (No fix recorded)
- simatic hmi comfort outdoor panels 7" & 15"All versions < V15.1 Update 1
- simatic hmi comfort panels 4" - 22"All versions < V15.1 Update 1
- simatic hmi ktp mobile panels ktp400f, ktp700, ktp700f, ktp900 und ktp900fAll versions < V15.1 Update 1
- simatic wincc runtime advancedAll versions < V15.1 Update 1
2 vendors · 16 products
References
3 links- www.us-cert.gov/ics/advisories/ICSA-19-134-09X Refsource MISC